PrecisionΒΆ
- Type:
float
- Range:
[1e-09, 1]
- Default:
0.05
- Appearance:
simple
This parameter controls the numerical accuracy of the near field. Decreasing it, will result in more accurate results. This parameter is also used as a termination criterion within the Refinement loop.
Warning
It is not guaranteed that after termination the precision of a quantity of interest as computed by a post-process is directly related to the value of this parameter.